LA-10(Q)(LAJ-10(Q)) current transformer

LA-10(Q) and LAJ-10(Q) are epoxy resin cast current transformers divided into semi-enclosed and fully enclosed. They are used for current, electric energy measurement and relay protection in power systems with rated voltage of 10kV and rated frequency of 50Hz or less for indoor devices.

Classification:

Current transformer

Key words:

transformer


Product Description

  1. Overview:

LA-10(Q) and LAJ-10(Q) are epoxy resin cast current transformers divided into semi-enclosed and fully enclosed. They are used for current, electric energy measurement and relay protection in power systems with rated voltage of 10kV and rated frequency of 50Hz or less for indoor devices.

LA-10(Q) [Replacement model: LFZ-10(Q), LDZ-10(Q)]

LAJ-10(Q)[Replacement model: LFZJ-10(Q), LDZJ-10(Q)]

  2. conditions of use:

The ambient temperature is -5 ℃ ~ 40 ℃, and the altitude is not more than 1000 meters. It can be used in Class II filthy areas.

  3. technical parameters:

1. Power factor of load COS φ = 0.8 (hysteresis)

2. Rated insulation level: 12/42/75kV

3. Rated secondary current: 5A or 1A

 

Rated current ratio

Level Combinations

Accurate grade and rated output (VA)

Accuracy Limits

Rated short time

Rated dynamic stability

Total weight

Product Model

(A)

Accuracy class and rated output

value coefficient

Thermal current

constant current

(kg)

Class

Type

Rated Current

 

 

 

 

 

Accurucy

(Ka)

(Ka)

Total

combination

0.2

0.5

1

3

10P

 

ratio

 

limitfactor

Ith

Idyn

weight

 

5~200/5

0.5/3

 

 

 

 

 

 

90Iin

160Iin

 

 

 

 

 

 

 

 

 

 

 

 

LA-10(Q)

300~400/5

1/3

10

10

10

15

15

10

75Iin

135Iin

 

 

0.5/10P10

 

 

 

500/5

60Iin

110Iin

 

 

 

 

 

 

 

 

 

 

 

1/10P10

 

 

 

 

 

 

 

 

 

 

600~1000/5

 

 

 

 

 

 

50Iin

90Iin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20~200/5

 

 

 

 

 

 

 

120Iin

215Iin

 

 

 

0.2/3

 

 

 

 

 

 

 

 

 

 

300/5

 

 

 

 

 

 

100Iin

180Iin

 

 

 

 

 

 

 

 

 

 

 

 

10P/15/10P15

 

 

 

 

 

 

 

 

 

LAJ-10(Q)

400/5

10

20

20

20

20

15

75Iin

135Iin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

500/5

 

 

 

 

 

 

60Iin

110Iin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

800~1000/5

 

 

 

 

 

 

 

50Iin

90Iin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  4. installation dimensions:

cccccc

  5. Ordering Instructions:

When ordering, the product model, rated current ratio, accurate level combination and corresponding rated output, rated short-time current, etc. shall be provided. For special orders can be negotiated with the factory to resolve.